Place of Origin |
Guangdong China (Mainland) |
Brand Name |
Pan-globe |
Model Number |
AP906 |
Usage |
Industrial |
Theory |
Temperature Controller |
Electronic temperature controllersFeatures:1. High control accuracy at the maximum of ±0.1oC;2. Double PID control functions, capable of controlling heating and cooling;3. General input, capable of selecting 56 kinds of different input information;4. A variety of output modes to greatly meet many requirements for load control;5. Can select PV (measurement value) or SV (set value) 4-20mA transmission output;6. Capable of selecting external remote control set value functions, for multiple unit synchronous setup;7. Output percentage restriction function and manual/automatic non-disturbance switching;8. Automatic diagnosis function, capable of displaying information on any failures;9. RS485 communication is available. Specifications: ModelP904P906P907P908P909P910Size(HxW)48 x 48mm48 x 96mm72 x 72mm96 x 48mm96 x 96mm80 x 160mmPower voltageAC85 - 265V, DC24V (optional)Power frequency50 / 60HzPower consumptionApprox 3VAApprox 4VAApprox 4VAApprox 4VAApprox 4VAApprox 4VAMemoryPower disconnection preserve memory E2 PROMInputSensing signal input. Sampling time: 500ms, display accuracy: 0.2% of FSThermocouples: K, J, R, S, B, E, N, T, W, U, LThermal Resistance: Pt100,Pt 50Linear signals: 4-20mA, 0-20mA, 1-5V, 0-5VOutputRelay contact:3A/220V, electric life: 100,000 times or more (under rated load), operation cycle 15 secondsPulse voltage: drive SSR, DC0/24V,ON: 24V, OFF: 0V. Operation cycle 1 secondLinear signals: 4-20mA, 0-5V, 0-20mA, 0-10V, 1-5V various standard signal outputPortion motor control output: control 3-line portion motor making it on or off, capable of displaying its openness of valvesSCR zero position trigger signals: direct trigger SCR for single-phase or 3-phase, zero position controlSCR phase trigger signals: direct trigger SCR for single-phase or 3-phase controlControlControl mode: PID, ON/OFF, Phase PID, continuous PID, self-regulated PID, fuzzy PID, location portion controlSet range: percentage band P:0-200.0%, integral time I: 0-3600 seconds, differential timeD: 0-900 secondsAccuracyControl accuracy: ±1oCMeasurement accuracy: ±0.5%FS (±0.2% which can be provided)Resolution:14BITSampling cycle: 0.5 sGeneral specificationsPower voltage: support AC85-265V,50/60Hz,DC24VOperating ambience: -10 50,30 90%RHConsumed power: 10VAWeight: 0.3kg or lessInsulation insulating resistance >20MΩ(500VDC), intensity 1500VAC/1 minute Ordering information: